The solution for multiple rooms

Multi-split systems are a solution that offers the possibility to air-condition several rooms at the same time using only one outdoor unit. A multi-split system allows 2 to 5 indoor units to be installed on a single unit, saving considerable space while retaining all the benefits of single-split units – the operating parameters of each indoor unit can be set individually, depending on the needs of the occupants in the room.

A wide range of indoor units (wall units, duct units, cassette units, ceiling units) with different cooling capacities makes Sevra multi systems suitable for office, hotel, service and residential spaces.

SAVINGS

SPACE-SAVING INSTALLATION

Connecting multiple indoor units to a single unit reduces the number of outdoor units needed compared to single split systems, resulting in significant space savings on building facades, roofs and balconies.

FEATURES OF THE DEVICE

OUTDOOR UNITS

OUTDOOR UNIT
FEATURES

Inverter technology
R32
refrigerant
Auto
restart
Heating at low temperatures
Cooling at low temperatures
Intelligent defrosting
Hydrophilic aluminum blades
Blue fins
of the exchanger
Super
§EMC
Start
at low voltage

CONTROL

CONVENIENT
CONTROL

180° sine wave control

The DC inverter compressor uses 180° sinusoidal control. This technique makes the compressor motor run smoothly and efficiency increases significantly.

SPECIFICATIONS

TECHNICAL DATA

Outdoor unit SEV-2M14 SEV-2M18 SEV-3M21
Cooling capacity [kW] 4,10 (1,80 – 4,51) 5,30 (2,00 – 5,83) 6,20 (2,20 – 6,71)
[Btu/h] 13989 (6142 – 15388) 18084 (6824 – 19892) 21154 (7506 – 22895)
Heating capacity [kW] 4,80 (2,05 – 5,28) 5,60 (2,21 – 6,16) 6,60 (2,39 – 7,26)
[Btu/h] 16378 (6995 – 18015) 19107 (7541 – 21017) 22519 (8155 – 24771)
Power supply [V,Hz,Ph] 220-240, 50, 1 220-240, 50, 1 220-240, 50, 1
Power consumption Cooling [W] 1240 1750 1920
Heating [W] 1150 1540 1780
Current consumption Cooling [A] 5,40 7,60 8,30
Heating [A] 5,00 6,70 7,80
SEER 6,16 7,07 6,57
SCOP 4,06 4,08 4,38
Energy efficiency class Cooling A++ A++ A++
Heating A+ A+ A+
Air flow rate [m3/h] 2300 2300 3100
Sound pressure level [dB(A)] 54 55 56
Sound power level [dB(A)] 61 62 65
Unit dimensions Unit [mm] 800 x 315 x 545 800 x 315 x 545 834 x 328 x 655
Packaging [mm] 920 x 400 x 620 920 x 400 x 620 945 x 435 x 725
Unit net / gross weight [kg] 34,0 / 37,0 36,0 / 39,0 44,0 / 47,0
Refrigeration pipes Liquid [mm(inch)] 2 x 6,35 (1/4) 2 x 6,35 (1/4) 3 x 6,35 (1/4)
Gas [mm(inch)] 2 x 9,52 (3/8) 2 x 9,52 (3/8) 3 x 9,52 (3/8)
Maximum installation length
indoor unit – outdoor unit
[m] 25 25 30
Maximum height difference
indoor unit – outdoor unit
[m] 15 15 15
Temperature range Cooling [°C] -15 ~ 52 -15 ~ 52 -15 ~ 52
Heating [°C] -15 ~ 24 -15 ~ 24 -15 ~ 24
Outdoor unit SEV-3M27 SEV-4M36 SEV-5M42
Cooling capacity [kW] 7,90 (2,30 – 8,69) 10,50 (2,50 – 11,00) 12,00 (2,77 – 12,70)
[Btu/h] 26955 (7848 – 29650) 35826 (8530 – 37532) 40944 (9451 – 43332)
Heating capacity [kW] 8,20 (2,45 – 9,02) 11,00 (2,67 – 11,20) 13,00 (2,96 – 13,10)
[Btu/h] 27978 (8359 – 30776) 37532 (9110 – 38214) 44356 (10100 – 44800)
Power supply [V~,Hz,Ph] 220-240, 50, 1 220-240, 50, 1 220-240, 50, 1
Power consumption Cooling [W] 2460 3950 4450
Heating [W] 2270 3150 3750
Current consumption Cooling [A] 10,70 17,5 19,72
Heating [A] 9,80 13,96 16,62
SEER 6,30 6,10 6,10
SCOP 4,04 4,00 4,10
Energy efficiency class Cooling A++ A++ A++
Heating A+ A+ A+
Air flow rate [m3/h] 3100 4000 4200
Sound pressure level [dB(A)] 58 61 61
Sound power level [dB(A)] 65 68 68
Unit dimensions Unit [mm] 834 x 328 x 655 985 x 395 x 808 985 x 395 x 808
Packaging [mm] 945 x 435 x 725 1105 x 495 x 895 1105 x 495 x 895
Unit net / gross weight [kg] 46,0 / 49,0 74,0 / 78,0 75,0 / 79,0
Refrigeration pipes Liquid [mm(inch)] 3 x 6,35 (1/4) 4 x 6,35 (1/4) 5 x 6,35 (1/4)
Gas [mm(inch)] 3 x 9,52 (3/8) 4 x 9,52 (3/8) 5 x 9,52 (3/8)
Maximum installation length
indoor unit – outdoor unit
[m] 30 35 35
Maximum height difference
indoor unit – outdoor unit
[m] 15 15 15
Temperature range Cooling [°C] -15 ~ 52 -15 ~ 52 -15 ~ 52
Heating [°C] -15 ~ 24 -15 ~ 24 -15 ~ 24

 

The air conditioning units contain the fluorinated greenhouse gas R32. Specifications, design and functions of the units are subject to change without prior notice. Pictures of appliances are used for illustration purposes only, actual appearance may differ from the illustration shown. Energy efficiency class stated for cooling operation.

FEATURES OF THE DEVICE

WALL-MOUNTED UNITS

FEATURES OF WALL-MOUNTED UNITS

Inverter technology
R32
refrigerant
Auto
restart
Super
EMC
Intelligent defrosting
Start
at low voltage
Blue fins
of the exchanger
Heating
at low temperatures
Standby
mode
TURBO
mode
Rapid
cooling / heating
Long-range
air flow
Intelligent backlighting
4
fan speeds
Movable
air louvers
Vertical
movement of the blinds
Anti-Cold
function
I FEEL
function
Night
mode
Modern
design
Honeycomb
filter
Optional
filters
Cold
Plasma Ionizer
Filter
contamination indication
LED
display
Self-diagnosis
function
Timer
Double-sided
condensation drainage
Fast and easy
installation
Built-in
Wi-Fi module
Wireless
controller
Cooling
mode
Heating
mode
Fan
mode
Dehumidification mode
Automatic
mode

CONDENSATE DRAIN

DOUBLE-SIDE
CONDENSATE DRAIN

The refrigerant feed and condensate drain piping can be connected to both the left and right sides of the indoor unit, making it much easier to adapt the installation location to the room layout.

SPECIFICATIONS

TECHNICAL DATA

Indoor unit SEV-09JO/I SEV-12JO/I SEV-18JO/I SEV-24JO/I
Cooling capacity [kW] 2,70 (0,60 – 4,00) 3,50 (0,80-4,10) 5,30 (1,30 – 5,70) 7,20 (1,80 – 7,40)
Heating capacity [kW] 3,00 (0,80 – 4,20) 3,80 (1,00 – 4,20) 5,30 (1,30 – 5,50) 7,20 (1,80 – 8,00)
Power supply [V,Hz,Ph] 220-240, 50, 1 220-240, 50, 1 220-240, 50, 1 220-240, 50, 1
Current consumption Cooling [A] 3,80 5,60 7,80 10,00
Heating [A] 3,70 4,90 6,50 9,50
Maximum current consumption [A] 9,50 9,50 12,00 16,00
Maximum power consumption [W] 1800 1900 2500 3400
Air flow rate (Tur./High/Mid/Low) [m3/h] 600 / 540 / 500 / 430 600 / 550 / 500 / 400 900 / 730 / 650 / 550 1300 / 1200 / 1010 / 870
Sound pressure level (Tur./High/Mid/Low) [dB(A)] 40 / 43 / 30 / 26 / 22 43 / 40 / 36 / 29 / 23 45 / 38 / 33 / 28 / 23 50 / 46 / 39 / 34 / 27
Sound power level [dB(A)] 54 53 59 63
Dimensions of the unit [mm] 792 x 292 x 201 792 x 292 x 201 904 x 316 x 224 1132 x 330 x 232
Net unit weight [kg] 8,0 8,5 11,0 14,0
Refrigeration pipes Liquid [mm(inch)] 6,35 (1/4) 6,35 (1/4) 6,35 (1/4) 6,35 (1/4)
Gas [mm(inch)] 9,52 (3/8) 9,52 (3/8) 12,70 (1/2) 15,88 (5/8)
Condensate [mm] 16,5 16,5 16,5 16,5

 

The air conditioning units contain the fluorinated greenhouse gas R32. Specifications, design and functions of the units are subject to change without prior notice. Pictures of appliances are used for illustration purposes only, actual appearance may differ from that shown. Energy efficiency class stated for cooling operation.

ACCESSORIES

ACCESSORIES

WIRELESS CONTROLLER
TYPE-T INCLUDED

FEATURES OF THE DEVICE

FLOOR / CEILING UNITS

FEATURES OF FLOOR / CEILING UNITS

Inverter technology
R32
refrigerant
Auto
restart
Super
EMC
Hydrophilic
aluminum blades
Start
at low voltage
Heating
at low temperatures
Cooling
at low temperatures
Intelligent
defrosting
Blue fins
of the exchanger
ECO mode -
energy saving
TURBO
mode
Silent
operation mode
Night
mode
Rapid
cooling / heating
Movable
air louvers
Vertical
movement of the louvers
4D
air flow
Durable
air filter
Mould
protection function
LED
display
Self-diagnosis
function
Compact
design
Cooling
mode
Heating
mode
Fan
mode
Dehumidification
mode
Automatic
mode
Wired
controller
Central
controller
Wi-Fi
control

AIR FLOW

4D AIRFLOW

The automatic vertical and horizontal movement of the indoor unit’s louvers ensures optimal air circulation in the room and even temperature distribution. The cooled air spreads in all directions, quickly reaching even the most remote zones in the room.

SPECIFICATIONS

TECHNICAL DATA

Indoor unit SEV-09MF SEV-12MF SEV-18MF
Cooling capacity [kW] 2,80 (1,50 – 3,55) 3,60 (1,70 – 3,70) 5,3 (2,50 – 5,6)
[Btu/h] 9560 (5120 – 12115) 12285 (5800 – 12625) 18080 (8530 – 19107)
Heating capacity [kW] 3,00 (1,60 – 3,81) 3,90 (2,03 – 4,42) 5,80 (3,03 – 7,03)
[Btu/h] 10240 (5460 – 13000) 13306 (6930 – 15080) 19790 (10340 – 24000)
Power supply [V,Hz,Ph] 220-240, 50, 1 220-240, 50, 1 220-240, 50, 1
Power consumption Cooling [W] 80 (20 – 125) 80 (20 – 125) 80 (20 – 125)
Heating [W] 80 (20 – 125) 80 (20 – 125) 80 (20 – 125)
Air flow rate [m3/h] 750 / 600 / 500 750 / 600 / 500 850 / 700 / 600
Sound pressure level [dB(A)] 39 / 36 / 30 39 / 36 / 30 45 / 42 / 40
Sound power level [dB(A)] 55 55 59
Dimensions of the unit [mm] 929 x 660 x 205 929 x 660 x 205 929 x 660 x 205
Unit net / gross weight [kg] 26 / 31 26 / 31 26 / 31
Refrigeration pipes Liquid [mm(inch)] 6,35 (1/4) 6,35 (1/4) 6,35 (1/4)
Gas [mm(inch)] 12,70 (1/2) 12,70 (1/2) 12,70 (1/2)
Condensate [mm(inch)] 20 20 20

 

Air conditioning units contain the fluorinated greenhouse gas R32. Specifications, design and functions of the units are subject to change without prior notice. Pictures of appliances are used for illustration purposes only, actual appearance may differ from the illustration shown. Energy efficiency class stated for cooling operation.

ACCESSORIES

ACCESSORIES

WIRELESS CONTROLLER
TYPE-K INCLUDED

WIRELESS CONTROLLER
TYPE-L OPTIONAL

WIRELESS CONTROLLER
XK-05 OPTIONAL

FEATURES OF THE DEVICE

CASSETTE UNITS

FEATURES OF CASSETTE UNITS

Inverter technology
R32
refrigerant
Auto
restart
Super
EMC
Hydrophilic
aluminum blades
Start
at low voltage
Heating
at low temperatures
Cooling
at low temperatures
Intelligent
defrosting
Blue fins
of the exchanger
Fireproof
electrical box
Built-in
condensate pump
360°
multi-directional
air supply
TURBO
mode
Night
mode
Rapid
cooling / heating
Movable
air louvers
I FEEL
function
Washable
air filter
Mould
protection function
Digital
display
Timer
Self-diagnosis
function
Cooling
mode
Heating
mode
Fan
mode
Dehumidification
mode
Automatic
mode
Wired
controller
Central
controller
Wi-Fi
control

CONDENSATE PUMP

BUILT-in
condensate pump

The unit is equipped with a high-lift condensate pump that discharges condensate water up to 1,200 mm above the level of the condensate tray. This allows flexible connection of the condensate drainage pipework in the false ceiling space.

SPECIFICATIONS

TECHNICAL DATA

Indoor unit SEV-09MC SEV-12MC SEV-18MC
Cooling capacity [kW] 2,80 (1,50 – 3,55) 3,60 (1,70 – 3,70) 5,0 (2,50 – 5,60)
[Btu/h] 9560 (5120 – 12115) 12285 (5800 – 12625) 17060 (8530 – 19107)
Heating capacity [kW] 3,00 (1,60 – 3,81) 3,90 (2,03 – 4,42) 5,60 (3,03 – 7,03)
[Btu/h] 10240 (5460 – 13000) 13306 (6930 – 15080) 19107 (10340 – 24000)
Power supply [V,Hz,Ph] 220-240, 50, 1 220-240, 50, 1 220-240, 50, 1
Power consumption Cooling [W] 70 (17,5 – 109) 70 (17,5 – 109) 70 (17,5 – 109)
Heating [W] 70 (17,5 – 109) 70 (17,5 – 109) 70 (17,5 – 109)
Air flow rate [m3/h] 700 / 600 / 530 700 / 600 / 530 700 / 600 / 530
Sound pressure level [dB(A)] 45 / 41 / 35 45 / 41 / 35 45 / 41 / 35
Sound power level [dB(A)] 56 56 56
Dimensions of the unit [mm] 570 x 570 x 260 570 x 570 x 260 570 x 570 x 260
Panel dimensions   [mm] 650 x 650 x 55 650 x 650 x 55 650 x 650 x 55
Unit net/gross weight [kg] 18,0 / 21,0 18,0 / 21,0 18,0 / 21,0
Panel net/gross weight [kg] 2,2 / 3,7 2,2 / 3,7 2,2 / 3,7
Refrigeration pipes Liquid [mm(inch)] 6,35 (1/4) 6,35 (1/4) 6,35 (1/4)
Gas [mm(inch)] 12,70 (1/2) 12,70 (1/2) 12,70 (1/2)
Condensate [mm(inch)] 20 20 20

 

Air conditioning units contain the fluorinated greenhouse gas R32. Specifications, design and functions of the units are subject to change without prior notice. Pictures of appliances are used for illustration purposes only, actual appearance may differ from that shown. Energy efficiency class stated for cooling operation.

ACCESSORIES

ACCESSORIES

WIRELESS CONTROLLER
TYPE-K INCLUDED

WIRELESS CONTROLLER
TYPE-L OPTIONAL

WIRELESS CONTROLLER
XK-05 OPTIONAL

FEATURES OF THE DEVICE

DUCTED UNITS

FEATURES OF DUCTED UNITS

Inverter technology
R32
refrigerant
Auto
restart
Super
EMC
Hydrophilic
aluminum blades
Start
at low voltage
Heating
at low temperatures
Cooling
at low temperatures
Intelligent defrosting
Blue fins
of the exchanger
High
ESP
Built-in
condensate pump
TURBO
mode
Night
mode
Rapid
cooling / heating
"Light Sensation"
function
Durable
air filter
Filter
contamination indication
Mould
protection function
Timer
Self-diagnosis
function
Compact
design
Cooling
mode
Heating
mode
Fan
mode
Dehumidification
mode
Automatic
mode
Wired
controller
Central
controller
Wi-Fi
control

FLAT DESIGN

EXCEPTIONAL
FLAT DESIGN

The multi SEVRA ducted units are only 20cm high, making them ideal for rooms with limited installation space.

SPECIFICATIONS

TECHNICAL DATA

Internal unit SEV-07MD SEV-09MD SEV-12MD SEV-18MD
Cooling capacity [kW] 2,20 (1,13 – 2,70) 2,60 (1,50 – 3,55) 3,60 (1,71 – 3,85) 5,10 (2,50 – 5,80)
[Btu/h] 7506 (3855 – 9220) 8872 (5120 – 12115) 12280 (5835 – 13135) 17400 (8530 – 19790)
Heating capacity [kW] 2,50 (1,34 – 3,17) 2,90 (1,70 – 3,65) 4,00 (1,90 – 3,92) 5,08 (2,84 – 6,40)
[Btu/h] 8530 (4575 – 10820) 9895 (5800 – 12450) 13650 (6480 – 13375) 19790 (9690 – 21835)
Power supply [V,Hz,Ph] 220-240, 50, 1 220-240, 50, 1 220-240, 50, 1 220-240, 50, 1
Power consumption Cooling [W] 55 55 55 75
Heating [W] 55 55 55 75
Air flow [m3/h] 600 / 450 / 380 600 / 450 / 380 680 / 560 / 450 860 / 660 / 600
Sound pressure level [dB(A)] 35 / 31 / 28 35 / 31 /.28 38 / 34 / 31 42 / 38 / 36
Sound power level [dB(A)] 53 53 53 55
ESP available compression [PA] 10 10 10 10
Unit dimensions [mm] 700 x 470 x 200 700 x 470 x 200 700 x 470 x 200 1000 x 470 x 200
Net/gross weight of unit [kg] 18,5 / 22,0 18,5 / 22,0 18,5 / 22,0 24,0 / 28,0
Cooling pipes Liquid [mm(cale)] 6.35 (1/4) 6.35 (1/4) 6.35 (1/4) 6.35 (1/4)
Gaz [mm(cale)] 12,70 (1/2) 12,70 (1/2) 12,70 (1/2) 12,70 (1/2)
Condensate [mm(cale)] 16,5 16,5 16,5 16,5

 

Air conditioning units contain the fluorinated greenhouse gas R32. Specifications, design and functions of the units are subject to change without prior notice. Pictures of appliances are used for illustration purposes only, actual appearance may differ from the illustration shown. Energy efficiency class stated for cooling operation.

ACCESSORIES

ACCESSORIES

WIRELESS CONTROLLER
TYPE-K INCLUDED

WIRELESS CONTROLLER
TYPE-L OPTIONAL

WIRELESS CONTROLLER
XK-05 OPTIONAL