Commercial systems – a solution for offices, hotels, conference rooms
SEVRA’s high-efficiency units are ideal for large spaces that require efficient air conditioning – in retail and service premises, offices, meeting rooms and other commercial spaces.
Thanks to the use of a high-efficiency DC inverter compressor, adjustable fan motor and advanced vector control technology using a 180º sine wave, Sevra commercial systems achieve high energy efficiencies – SEER from 6.1 and SCOP from 4.0. The units meet all European Union requirements for energy efficiency.
The DC inverter compressor uses 180° sinusoidal control. This technique makes the compressor motor run smoothly and efficiency increases significantly.
The unit works with the latest environmentally friendly refrigerant R32, which has greater efficiency and a lower greenhouse effect coefficient, compared to refrigerant R410A. It also does not cause damage to the ozone layer.
SEVRA commercial systems are characterised by stable operation even in extreme ambient temperatures. Thanks to the use of state-of-the-art technology, SEVRA air conditioners operate reliably from an outdoor temperature of -15°C in cooling mode and -15°C in heating mode, providing a high level of comfort at any time of the year.
Additional air vents in the corners of the cassette unit panel ensure that air is blown in all directions (360° supply mode). This ensures an even distribution of conditioned air in the room and optimal conditions even over a large area.
The unit runs on the latest environmentally friendly refrigerant R32, which has greater efficiency and a lower greenhouse effect coefficient, compared to R410A refrigerant.
Additional air vents in the corners of the cassette unit panel ensure that air is blown in all directions (360° supply mode).
The cassette unit can be optionally equipped with a WiFi module, which allows the operation of the air conditioner to be controlled from a smartphone, tablet or computer connected to the internet, from anywhere in the world.
| Model | SEV-12CAC | SEV-18CAC | SEV-24CAC | SEV-36CAC | ||
|---|---|---|---|---|---|---|
| Cooling capacity | [kW] | 3,60 (1,35 – 4,40) | 5,00 (1,53 – 5,60) | 7,00 (2,16 – 8,20) | 10,55 (2,90 – 13,00) | |
| [Btu/h] | 12000 (4600 – 15000) | 18000 (5200 – 19100) | 24000 (7400 – 28000) | 36000 (9800-44300) | ||
| Heating capacity | [kW] | 4,20 (1,24 – 5,30) | 5,60 (1,40 – 6,20) | 8,00 (1,98 – 9,30) | 11,15 (2,60 – 13,50) | |
| [Btu/h] | 14300 (4200 – 18100) | 19100 (4800 – 21200) | 27300 (6800 – 31700) | 38000 (8800 – 46000) | ||
| Power supply | [V,Hz,Ph] | 220-240, 50, 1 | 220-240, 50, 1 | 220-240, 50, 1 | 220-240, 50, 1 | |
| SEER | [W/W] | 6,20 | 6,30 | 6,50 | 6,10 | |
| SCOP | [W/W] | 4,10 | 4,00 | 4,20 | 4,00 | |
| Energy efficiency class | Cooling | – | A++ | A++ | A++ | A++ |
| Heating | – | A+ | A+ | A+ | A+ | |
| Indoor unit | SEV-12CAC | SEV-18CAC | SEV-24CAC | SEV-36CAC | ||
| Air flow rate | [m3/h] | 700 / 600 / 530 | 700 / 600 / 530 | 1300 / 1050 / 950 | 1800 / 1550 / 1350 | |
| Sound pressure level | [dB(A)] | 45 / 44 / 36 | 45 / 44 / 36 | 47 / 43 / 38 | 51 / 48 / 45 | |
| Sound power level | [dB(A)] | 56 | 56 | 57 | 62 | |
| Dimensions of the unit | [mm] | 570 x 570 x 260 | 570 x 570 x 260 | 835 x 835 x 250 | 835 x 835 x 290 | |
| Panel dimensions | [mm] | 650 x 650 x 55 | 650 x 650 x 55 | 950 x 950 x 55 | 950 x 950 x 55 | |
| Unit net / gross weight | [kg] | 17,0 / 20,0 | 17,0 / 20,0 | 24,0 / 27,5 | 26,5 / 30,5 | |
| Panel net / gross weight | [kg] | 2,2 / 3,7 | 2,2 / 3,7 | 5,3 / 7,8 | 5,3 / 7,8 | |
| Condensate drain | [mm (inch)] | DN20 (R3/4) | DN20 (R3/4) | DN20 (R3/4) | DN20 (R3/4) | |
| Outdoor unit | SEV-12CAO | SEV-18CAO | SEV-24CAO | SEV-36CAO | ||
| Air flow rate | [m3/h] | 2600 | 2600 | 3750 | 4000 | |
| Sound pressure level | [dB(A)] | 54 | 55 | 58 | 57 | |
| Sound power level | [dB(A)] | 64 | 64 | 67 | 66 | |
| Dimensions of outdoor unit | [mm]. | 800 x 315 x 545 | 800 x 315 x 545 | 900 x 350 x 700 | 970 x 395 x 805 | |
| Weight of outdoor unit net / gross | [kg] | 35,0 / 38,0 | 37,0 / 40,0 | 51,0 / 55,0 | 72,0 / 76,0 | |
| Refrigeration pipes | Liquid | [mm(inch)] | 6,35 (1/4) | 6,35 (1/4) | 9,52 (3/8) | 9,52 (3/8) |
| Gas | [mm(inch)] | 12,70 (1/2) | 12,70 (1/2) | 15,88 (5/8) | 15,88 (5/8) | |
| Maximum installation length | [m] | 25 | 30 | 50 | 65 | |
| Maximum height difference | [m] | 10 | 20 | 25 | 30 | |
| Model | SEV-42CAC | SEV-48CAC | SEV-60CAC | ||
|---|---|---|---|---|---|
| Cooling capacity | [kW] | 12,10 (2,90 – 13,5) | 14,00 (4,76 – 16,50) | 16,00 (4,76 – 17,50) | |
| [Btu/h] | 42000 (9800 – 46000) | 48000 (16241 – 56298) | 55000 (16241 – 59710) | ||
| Heating capacity | [kW] | 13,50 (2,60 – 15,00) | 16,00 (4,78 – 16,15) | 17,00 (4,78 – 18,50) | |
| [Btu/h] | 46000 (8800 – 51100) | 55000 (16309 – 55104) | 58000 (16308 – 63122) | ||
| Power supply | [V,Hz,Ph] | 220-240, 50, 1 | 380-415, 50, 3 | 380-415, 50, 3 | |
| SEER | [W/W] | 6,10 | 6,10 | 6,10 | |
| SCOP | [W/W] | 4,00 | 4,00 | 4,00 | |
| Energy efficiency class | Cooling | – | A++ | A++ | A++ |
| Heating | – | A+ | A+ | A+ | |
| Indoor unit | SEV-42CAC | SEV-48CAC | SEV-60CAC | ||
| Air flow rate | [m3/h] | 1800 / 1550 / 1350 | 1950 / 1750 / 1500 | 1950 / 1750 / 1500 | |
| Sound pressure level | [dB(A)] | 51 / 48 / 45 | 52 / 50 / 48 | 52 / 50 / 48 | |
| Sound power level | [dB(A)] | 62 | 65 | 65 | |
| Dimensions of the unit | [mm] | 835 x 835 x 290 | 835 x 835 x 290 | 835 x 835 x 290 | |
| Panel dimensions | [mm] | 950 x 950 x 55 | 950 x 950 x 55 | 950 x 950 x 55 | |
| Unit net / gross weight | [kg] | 26,5 / 30,5 | 31,0 / 35,0 | 31,0 / 35,0 | |
| Panel net / gross weight | [kg] | 5,3 / 7,8 | 5,3 / 7,8 | 5,3 / 7,8 | |
| Condensate drain | [mm (inch)] | DN20 (R3/4) | DN20 (R3/4) | DN20 (R3/4) | |
| Outdoor unit | SEV-42CAO | SEV-48CAO | SEV-60CAO | ||
| Air flow rate | [m3/h] | 4200 | 7200 | 7200 | |
| Sound pressure level | [dB(A)] | 57 | 60 | 60 | |
| Sound power level | [dB(A)] | 66 | 70 | 70 | |
| Dimensions of outdoor unit | [mm]. | 970 x 395 x 805 | 940 x 370 x 1325 | 940 x 370 x 1325 | |
| Weight of outdoor unit net / gross | [kg] | 72,0 / 76,0 | 92,0 / 102,0 | 92,0 / 102,0 | |
| Refrigeration pipes | Liquid | [mm(inch)] | 9,52 (3/8) | 9,52 (3/8) | 9,52 (3/8) |
| Gas | [mm(inch)] | 15,88 (5/8) | 19,05 (3/4) | 19,05 (3/4) | |
| Maximum installation length | [m] | 65 | 65 | 65 | |
| Maximum height difference | [m] | 30 | 30 | 30 | |
The air-conditioning units contain the fluorinated greenhouse gas R32.
The photos of the units are for illustration purposes only, the actual appearance may differ.
Specifications, design and functions are subject to change without prior notice.